EPM1500-42
1500W 48V TO 220/230Vac PURE SINE WAVE INVERTER
Single phase Pure sine wave inverter
Surge Power <3000W,Frequency50/60Hz
- Adoption of advanced SPWM technology, pure sine wave output
- Dynamic current loop control technology to ensure inverter reliable operation
- Wide DC input voltage range
- Low output harmonic distortion(THD≤2%)
- LED indicators for input voltage range, normal output & failure state
- Extensive protections: short-circuit, overload, under/over input voltage, over-temperature, and inverter's inner fault identification protections
- Temperature, and inverter's inner fault identification protections
- The output voltage and frequency can be switched
- Complete isolation-type inverter technology
- Optional energy SAV mode(saving mode)
- Wide working temperature range (industrial level)
- Continuous operation at full power
Item |
EPM1500-41 |
EPM1500-42 |
Electrical Parameters |
||
Input rated voltage |
48V |
|
Input voltage range |
43.2~64Vdc |
|
No load current |
≤0.3A@48Vdc |
≤0.4A@48Vdc |
Output voltage |
110/127Vac |
220/230Vac |
Continuous power |
1500W |
|
Power 60sec |
1600~2300W |
|
Power 1.5sec |
2300~3000W |
|
Surge Power |
<3000W |
|
Output Mode |
Single-phase electricity |
|
Output wave |
Pure sine wave |
|
Frequency |
50/60Hz |
|
Diatortion THD |
THD≤2%(Resisitive load) |
|
Efficiency at full load *1 |
91.7% |
93.6% |
Max. efficiency *2 |
93.2% |
94.3% |
SAV mode |
0.18A; The load is detected every 10sec, if the output power is greaterthan 20W, it will output continuously |
0.17A; The load is detected every 10sec, if the output power is greaterthan 20W, it will output continuously |
DC current |
35A |
|
Shutdown status |
<1mA |
|
Fuse |
20A*4 |
|
Environment Parameters |
||
Dimension |
386*228*124.5mm |
|
Hole Size |
φ7mm |
|
Weight |
5Kg |
|
Working temperature |
-20℃~+50℃ |
|
Storage temperature |
-35℃~+70℃ |
|
Humidity |
<95%(N.C.) |
|
Altitude |
<5000m(Derating to operate accoding to IEC62040 at a height exceeding 1000m) |
|
Other Parameters |
||
Insulation |
Between AC output terminals and metal case: ≥550MΩ |
|
Dielectric strenth |
Between AC output terminals and metal case: Test voltage AC1500V, 1min |
|
Application |
Household appliances, cars, solar system and so on |